Medical water treatment system
Stable water quality, no dead angles, fully verified, safe and compliant.
Design Basis
1.According to the detailed water quality report provided by the user, "tailor-made".
2.Sterile and implantable medical devices "Inspection and Evaluation Standards".
3.The latest version of "Chinese Pharmacopoeia".
4.Water quality standards for purified water and water for injection.
Prevent the Growth of Microorganisms
The details of the treatment of the purified water system and injection water system used in medical devices often determine the safety and reliability of the system. During the production process of NetDerui, the dead angle of the system is eliminated by design, welding, surface treatment, etc. The water produced by the system is stable and reliable, and it is produced and processed strictly in accordance with the technological requirements and design drawings.
Design Features
1.Modular design of the entire system, three-dimensional simulation design and installation.
2.The wiring of each unit is completed in the factory, reducing the installation and commissioning time.
3.Comply with cGMP, ISPE/FDA guidelines, and comply with EU CE certification requirements.
4.The pipeline is made of 304/316L material; sanitary and non-hygienic design.
Normal temperature type / hot water disinfection type.
5.Stainless steel pipeline trend diagram, welding spot arrangement, welding record, endoscope inspection.
6.The pipeline inlet section has a corresponding slope and no dead angle design.
7.Integrated control system and integrated instrument system, etc., convenient operation and management.
General Service
1.FAT acceptance test: Provide detailed FAT factory acceptance test report.
2.Related training services: System operation management, daily operation management standard mechanism, etc.
3.After-sales service:
(1) Quick response service for customer problem feedback – put forward solutions in 30 minutes, and arrive at the site for free repair within 24 hours at the fastest.
(2) 7×24 hours free consultation service for life.
(3) Free follow-up guidance for life, reminder service for replacement of equipment consumables.
Complete Verification Service
Vaughan Environmental Protection can provide all verification documents, including the implementation of PQ draft.
1.Design confirmation (DQ)
2.Installation confirmation (IQ)
3.Operation confirmation (OQ)
Quality Assurance System
1.Standard operating procedures for piping and fittings and cleaning.
2.Standard specification operation process of automatic welding machine.
3.Standard operating procedure for pipeline cleaning.
4.Standard operating procedures for pipeline pressure test standards.
5.Pipeline pickling passivation standard specification operation process.
6.Standard operating procedures for system disinfection standards.
FAQ
-
What water quality standards does the Vaughan medical device water system meet?
It meets water quality standards for purified water and water for injection, the latest Chinese Pharmacopoeia, sterile and implantable medical device inspection standards, and is tailored to the user's water quality report.
-
How does the Vaughan system prevent microbial growth?
It eliminates dead angles through optimized design, precision welding, and surface treatment, ensuring stable and reliable water production strictly according to process requirements and design drawings.
-
What design features support compliance with international guidelines?
The system complies with cGMP, ISPE/FDA guidelines, and EU CE certification. It uses 304/316L sanitary piping, no-dead-angle design, slope compliance, endoscope inspection, and integrated control/instrument systems.
-
What verification documents does Vaughan provide?
Vaughan provides complete verification documents including Design Confirmation (DQ), Installation Confirmation (IQ), Operation Confirmation (OQ), and PQ draft implementation.
-
What after-sales services are offered?
Quick response (solution in 30 min, free on-site repair within 24 hours), 7×24 lifetime free consultation, lifetime free follow-up guidance, and consumable replacement reminders.